  "id": "urn:ngsi-ld:PhotovoltaicDevice:PhotovoltaicDevice:MNCA-PV-T2-R-012",
  "type": "PhotovoltaicDevice",
  "name": {
    "type": "Text",
    "value": "DEVICE-PV-T2-R-012"
  },
  "alternateName": {
    "type": "Text",
    "value": "AirPort \u2013 global Observation"
  },
  "description": {
    "type": "Text",
    "value": "Photo-voltaic Device description"
  },
  "location": {
    "type": "geo:json",
    "value": {
      "type": "Point",
      "coordinates": [
        43.66481,
        7.196545
      ]
    }
  },
  "address": {
    "type": "StructuredValue",
    "value": {
      "addressCountry": "FR",
      "addressLocality": "Nice",
      "streetAddress": "Airport - Terminal 2 - Roof 2 - Local  12"
    }
  },
  "areaServed": {
    "type": "Text",
    "value": "Nice Aeroport"
  },
  "refDevice": {
    "type": "Text",
    "value": "urn:ngsi-ld:Device:PV-T2-R-012"
  },
  "dateLastReported": {
    "type": "DateTime",
    "value": "2020-05-17T09:47:00Z"
  },
  "brandName": {
    "type": "Text",
    "value": "Canadian Solar"
  },
  "modelName": {
    "type": "Text",
    "value": "CS6P-270P"
  },
  "manufacturerName": {
    "type": "Text",
    "value": "Canadian Solar EMEA GmbH,"
  },
  "serialNumber": {
    "type": "StructuredValue",
    "value": [
      "CSPV270P-SN1804L6J34Z8742H",
      "CSPV270P-SN1804L6J34Z8743H",
      "CSPV270P-SN1804L6J34Z8744H",
      "CSPV270P-SN1804L6J34Z8745H",
      "CSPV270P-SN1804L6J34Z8746H"
    ]
  },
  "application": {
    "type": "StructuredValue",
    "value": [
      "electric"
    ]
  },
  "cellType": {
    "type": "StructuredValue",
    "value": [
      "polycrystalline"
    ]
  },
  "installationMode": {
    "type": "StructuredValue",
    "value": [
      "roofing"
    ]
  },
  "installationCondition": {
    "type": "StructuredValue",
    "value": [
      "extremeHeat",
      "extremeCold",
      "extremeClimate",
      "desert"
    ]
  },
  "possibilityOfUsed": {
    "type": "Text",
    "value": "stationary"
  },
  "integrationMode": {
    "type": "Text",
    "value": "IAB"
  },
  "documentation": {
    "type": "Text",
    "value": "https://www.myDevicePV.Cn"
  },
  "owners": {
    "type": "StructuredValue",
    "value": [
      "Airport-Division Maintenance"
    ]
  },
  "cellDimension": {
    "type": "StructuredValue",
    "value": {
      "length": 16.0,
      "width": 9.0,
      "thickness": 2.3
    }
  },
  "moduleNbCells": {
    "type": "Number",
    "value": 60
  },
  "moduleDimension": {
    "type": "StructuredValue",
    "value": {
      "length": 1600,
      "width": 975,
      "thickness": 3.75
    }
  },
  "panelNbModules": {
    "type": "Boolean",
    "value": true
  },
  "panelDimension": {
    "type": "StructuredValue",
    "value": {
      "length": 1638,
      "width": 982,
      "thickness": 40
    }
  },
  "panelWeight": {
    "type": "Number",
    "value": 18
  },
  "arealWeight": {
    "type": "Number",
    "value": 32
  },
  "maxPressureLoad": {
    "type": "StructuredValue",
    "value": {
      "hail": 2500,
      "snow": 5400,
      "wind": 2400
    }
  },
  "NominalPower": {
    "type": "Number",
    "value": 270
  },
  "MaximumSystemVoltage": {
    "type": "Number",
    "value": 1000
  },
  "applicationClass": {
    "type": "StructuredValue",
    "value": [
      "A"
    ]
  },
  "fireClass": {
    "type": "StructuredValue",
    "value": [
      "C"
    ]
  },
  "pTCClass": {
    "type": "Number",
    "value": 92.1
  },
  "nTCClass": {
    "type": "Number",
    "value": 88.3
  },
  "protectionIP": {
    "type": "Text",
    "value": "IP67"
  },
  "moduleSTC": {
    "type": "StructuredValue",
    "value": {
      "Pmax": 270,
      "Umpp": 30.8,
      "Impp": 8.75,
      "Uoc": 37.9,
      "Isc": 9.32
    }
  },
  "moduleNOCT": {
    "type": "StructuredValue",
    "value": {
      "Pmax": 196,
      "Umpp": 28.1,
      "Impp": 6.97,
      "Uoc": 34.8,
      "Isc": 7.55
    }
  },
  "moduleYieldRate": {
    "type": "Number",
    "value": 16.79
  },
  "panelOperatingTemperature": {
    "type": "StructuredValue",
    "value": {
      "min": -40,
      "max": 85
    }
  },
  "cellOperatingTemperature": {
    "type": "StructuredValue",
    "value": {
      "min": 45,
      "max": 2
    }
  },
  "temperatureCoefficient": {
    "type": "StructuredValue",
    "value": {
      "Pmax": -0.41,
      "Uoc": -0.31,
      "Isc": 0.053
    }
  },
  "performanceLowIrradiance": {
    "type": "Number",
    "value": 96.5
  },
  "panelLifetime": {
    "type": "Number",
    "value": 30
  },
  "panelYieldCurve": {
    "type": "StructuredValue",
    "value": [
      "95.0",
      "92.5",
      "90.0",
      "87.5",
      "85.0",
      "80.0"
    ]
  },
  "panelYieldRate": {
    "type": "Number",
    "value": 0.5
  },
  "panelTiltReference": {
    "type": "StructuredValue",
    "value": {
      "min": 28,
      "max": 37
    }
  }
}