  "id": "urn:ngsi-ld:InverterDevice:InverterDevice:MNCA-INVDEV-T1-G0-027",
  "type": "InverterDevice",
  "name": {
    "type": "Text",
    "value": "INVDEV-T1-G0-027"
  },
  "alternateName": {
    "type": "Text",
    "value": "AirPort \u2013 global Observation"
  },
  "description": {
    "type": "Text",
    "value": "Description of the Inverter linked to Battery and PhotoVoltaic Devices"
  },
  "location": {
    "type": "geo:json",
    "value": {
      "type": "Point",
      "coordinates": [
        43.66481,
        7.196545
      ]
    }
  },
  "address": {
    "type": "StructuredValue",
    "value": {
      "addressCountry": "FR",
      "addressLocality": "Nice",
      "streetAddress": "Airport - Terminal 1 - Ground 0 - Local  27"
    }
  },
  "areaServed": {
    "type": "Text",
    "value": "Nice Aeroport"
  },
  "dateLastReported": {
    "type": "DateTime",
    "value": "2020-03-17T08:45:00Z"
  },
  "brandName": {
    "type": "Text",
    "value": "KOSTAL ELEC"
  },
  "modelName": {
    "type": "Text",
    "value": "SB 4000TL-20"
  },
  "manufacturerName": {
    "type": "Text",
    "value": "SOLAR ELECTRIC CPY"
  },
  "serialNumber": {
    "type": "Text",
    "value": "SEKOPI10327458712"
  },
  "application": {
    "type": "StructuredValue",
    "value": [
      "robotics"
    ]
  },
  "typeOfUse": {
    "type": "Text",
    "value": "indoor"
  },
  "installationMode": {
    "type": "Text",
    "value": "wall"
  },
  "installationCondition": {
    "type": "StructuredValue",
    "value": [
      "extremeClimate"
    ]
  },
  "possibilityOfUse": {
    "type": "Text",
    "value": "stationary"
  },
  "documentation": {
    "type": "Text",
    "value": "https://www.myInverter.fr"
  },
  "owners": {
    "type": "StructuredValue",
    "value": [
      "Airport-Division Maintenance"
    ]
  },
  "phaseType": {
    "type": "Text",
    "value": "threePhase"
  },
  "supplyPhaseNb": {
    "type": "Number",
    "value": 3
  },
  "dimension": {
    "type": "StructuredValue",
    "value": {
      "length": 52.75,
      "depth": 23.5,
      "height": 45.25
    }
  },
  "weight": {
    "type": "Number",
    "value": 34
  },
  "protectionIP": {
    "type": "Text",
    "value": "55"
  },
  "protectionIK": {
    "type": "Number",
    "value": 10
  },
  "protectionClassSLK": {
    "type": "Text",
    "value": "1"
  },
  "overVoltageCategory": {
    "type": "Text",
    "value": "III"
  },
  "operatingTemperature": {
    "type": "StructuredValue",
    "value": {
      "min": -25,
      "max": 60
    }
  },
  "operatingAirHumidity": {
    "type": "StructuredValue",
    "value": {
      "min": 0,
      "max": 0.95
    }
  },
  "nominalPowerDC": {
    "type": "Number",
    "value": 4200
  },
  "nominalVoltageDC": {
    "type": "Number",
    "value": 400
  },
  "nominalAmpereDC ": {
    "type": "Number",
    "value": 17
  },
  "nominalFrequencyDC": {
    "type": "Number",
    "value": 50
  },
  "operatingVoltageDC": {
    "type": "StructuredValue",
    "value": {
      "min": 125,
      "max": 550
    }
  },
  "operatingAmpereDC": {
    "type": "StructuredValue",
    "value": {
      "min": 17,
      "max": 17
    }
  },
  "operatingFrequencyDC": {
    "type": "StructuredValue",
    "value": {
      "min": 50,
      "max": 50
    }
  },
  "mPPTPVVoltageDC": {
    "type": "StructuredValue",
    "value": {
      "min": 188,
      "max": 440
    }
  },
  "startingVoltageDC": {
    "type": "Number",
    "value": 150
  },
  "nbMPPTrackersDC": {
    "type": "Number",
    "value": 3
  },
  "nbInputParallelDC": {
    "type": "Text",
    "value": "A:2,B:2"
  },
  "maxInputCurrentParallelAssembly": {
    "type": "Number",
    "value": 25
  },
  "nominalPowerAC": {
    "type": "Number",
    "value": 3680
  },
  "maxOutputPowerAC": {
    "type": "Number",
    "value": 4000
  },
  "nominalVoltageAC": {
    "type": "Number",
    "value": 230
  },
  "nominalAmpereAC ": {
    "type": "Number",
    "value": 16
  },
  "nominalFrequencyAC": {
    "type": "Number",
    "value": 50
  },
  "operatingVoltageAC": {
    "type": "StructuredValue",
    "value": {
      "min": 180,
      "max": 280
    }
  },
  "operatingAmpereAC": {
    "type": "StructuredValue",
    "value": {
      "min": 16,
      "max": 22
    }
  },
  "operatingFrequencyAC": {
    "type": "StructuredValue",
    "value": {
      "min": 50,
      "max": 60
    }
  },
  "powerFactorAC": {
    "type": "Boolean",
    "value": true
  },
  "moduleYieldRate": {
    "type": "StructuredValue",
    "value": {
      "euro": 97.1,
      "eta": 96.4
    }
  },
  "noiseLevel": {
    "type": "Number",
    "value": 29
  },
  "self-consumption": {
    "type": "Number",
    "value": 0.5
  },
  "topology": {
    "type": "Text",
    "value": "without transformer"
  },
  "coolingSystem": {
    "type": "Text",
    "value": "OptiCool"
  },
  "inverterStatus": {
    "type": "StructuredValue",
    "value": [
      "00-OnSector",
      "06-OverVoltage"
    ]
  }
}